10 exam-style questions with answers and explanations, straight from our 1,030-question bank. Tap an answer to check yourself. When you're ready, take the scored version in the free practice test.
During a calendar month, a metal-parts manufacturer generates 80 kg of nonacute hazardous waste and 1.6 kg of acute hazardous waste. It generates no acute-waste spill residues and ships all of the waste off site before month-end. No counting exclusion or episodic-generation provision applies. Under federal RCRA rules, which classification and basis are correct for that month?
Show answer & explanation
Correct answer: C - Large quantity generator, because acute hazardous waste generation exceeds 1 kg.
Question 2
An engineer is considering a heated transfer line for a process chemical. Before selecting an operating temperature, the engineer needs to identify conditions that could destabilize the chemical and the hazardous products it could release on decomposition. Where in the Safety Data Sheet is that information principally located?
Show answer & explanation
Correct answer: A - Section 10: Stability and reactivity
Question 3
Two monitoring wells are screened in the same interval of an unconfined aquifer. Their measuring-point elevations use the same surveyed datum, and water levels are measured at the same time. The western well has a measuring-point elevation of 122 m and water 17 m below that point. The eastern well has an elevation of 118 m and water 11 m below its measuring point. Which interpretation of hydraulic head along this east-west line is supported?
Show answer & explanation
Correct answer: D - Head decreases westward: 107 m in the eastern well and 105 m in the western well.
Question 4
A manufacturer proposes rerouting process wastewater from a permitted surface-water outfall to a municipal sanitary sewer. The plant manager says, "The treatment plant has an NPDES permit, so our wastewater will be covered." What is missing from that assessment?
Show answer & explanation
Correct answer: B - The industrial discharge must satisfy applicable pretreatment and local sewer-discharge requirements.
Question 5
A 200 mL spill of a known, nonflammable dilute alkaline cleaner is contained in a compatible work tray. No one is exposed, no drain is threatened, and the assessment identifies no inhalation or fire hazard. Nearby employees are trained and equipped for this exact spill under a written absorption-and-collection procedure. Which response is proportionate to these conditions?
Show answer & explanation
Correct answer: B - Have the trained employees collect the spill using the established incidental-spill procedure.
Question 6
A chemical-blending plant could emit 12 tons per year of one hazardous air pollutant without operating restrictions. A federally enforceable permit restriction limits its potential to emit that pollutant to 8 tons per year; actual emissions are 6 tons per year. Combined potential emissions of all hazardous air pollutants are 18 tons per year, and no other individual hazardous air pollutant reaches 10 tons per year. No other Title V trigger applies. Which conclusion uses the correct permitting basis?
Show answer & explanation
Correct answer: D - It is not a major source because its restricted potential emissions are below both applicable hazardous-air-pollutant thresholds.
Question 7
A chronic oral exposure assessment reports a hazard quotient of 2.4 for one contaminant in drinking water. The exposure estimate and reference dose use compatible units and assumptions. A community briefing should explain this result as:
Show answer & explanation
Correct answer: A - A dose above the noncancer reference dose, warranting evaluation without predicting illness in exposed people.
Question 8
Records and site reconnaissance at a former degreasing shop identify a solvent drain that discharged to an unlined sump. The Phase I environmental site assessment identifies a release concern but contains no soil or groundwater results. There is no immediate exposure emergency. To determine whether those media were affected, the next scope of work should be:
Show answer & explanation
Correct answer: C - A targeted Phase II investigation of soil and groundwater around the sump and potential migration pathways.
Question 9
A facility has correctly identified a spent solvent as an F-listed hazardous waste based on a toxicity listing. Representative testing finds no hazardous-waste characteristic. No exclusion or delisting applies. The manager proposes removing the hazardous-waste designation because the laboratory results are below the characteristic thresholds. Which response resolves the issue?
Show answer & explanation
Correct answer: D - Retain the designation: a toxicity-based listing still applies when characteristic tests are negative.
Question 10
A packaging printer is comparing four technically feasible projects that all maintain product quality. Which project is pollution prevention through source reduction, rather than management of pollution after it is generated?
Show answer & explanation
Correct answer: A - Reformulate the ink to use less solvent per acceptable finished package.
That's 10 of 1,030